QF Manual Blast Gate NFMES
NordfabBlast Gates to manually balance the air flow with an energy saving design.
Nordfab QF Manual Blast Gates NFMES are manually operated, energy saving blast gates which shut off ductwork lines that aren't in use while saving energy and keep suction the strongest where you need it. For example, manually closing all but one gate will put the strongest possible dust or debris extraction in one particular location.
These compact and easy to operate gates are constructed of galvanized metal with a special sealing device that reduces air loss and friction in operation. They are also available in stainless steel and 3" - 16" diameters with QF rolled ends for easy connection to QF ductwork.
Quick-Fit ducting has been used in a wide variety of applications, wherever dust collection or fine particulate transfer is required. Its QF rolled ends for use with QF clamps, allow quick assembly, disassembly and relocation. It clamps together in seconds without welds, bolts, screws, flanges, special tools, precise measurements or specialized skills. So, it cuts installation – and ducting related downtime – by more than 40% over traditional ductwork. See more benefits below.
Product Features
- 3" - 16" diameters
- Manual operation type
- Energy Saving Design
- QF rolled edges
- Quick, simple assembly
Bisco can assist customers in designing a blast-gate system, taking into account flow dynamics that will be affected by blast gates. While blast gates can be used effectively, they can also destroy the flow if not properly placed. Contact Us for assistance.
Nordfab Blast Gates are also available in these styles:
Product Specifications
Diameter | 3 - 16 inch |
Height | 6.25" - 28.5" |
Width | 5.25" - 18" |
Depth | ≤4":5.38", ≥5":5" |
Weight | 2.7lbs - 21.5lbs |
Gauge | ≤12":22ga, ≥14":20ga |
Rating | Max Temp: 250° F |
Material | Galv, 304SS |
Duct Type | Quick Fit Duct |
Edge | Rolled, 0.2" - 0.4" |
Info & Guides
- Technical Data Sheet, QF Manual Blast Gate NFMES
- Temperature Guide, Nordfab Ductwork
- General Specifications, Nordfab Ductwork
- Installation Guide, Nordfab Ductwork
Questions & Answers
Do QF Clamps come with the blast gate? If not how many do I need to order?
Clamps do not come with this blast gate. As a rule, you will need one clamp per component ordered.
How do I connect to the end of an existing non QF system?
We offer a full line of adapters to connect to any existing pipe you might have.
When do I need to use stainless steel?
Stainless steel is used in FDA, chemical and high temperature applications.
Still have questions?
Browse our frequently asked questions page or contact us.
Discover the Benefits of Nordfab Ducting, "The World's Fastest Ducting™"
Fast Installation Easy Connection Strong & Leak Tight Versatile |
|